<LOGO>
FM Transmitter Measurement Report
Created: 2023-06-11 23-52-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.60 MHz 5/5, 81 dBuV RTL2
Pilot RDS Phase Difference
6.8 kHz 4.1 kHz 36 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
19 kHz 73 kHz 17111 10,3851
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
5,1 dBr 6,13 dBr 6,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 --:--
RT
-
AF EON
88.2, 94.4, 96.2, 96.4, 96.6, 98.0, 98.2, 105.1, 105.9, 106.0, 106.1 MHz -
FM Scope Station: 96.60 MHz, signal: 5/5 (81 dBuV) Max at: 73 kHz MIN: 19 kHz % above 75 kHz: 10,3851 Acquired: 2023/06/11 23:51:01 Total samples: 17111 Equivalent time: 0:14:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 6,8 dBr MIN: 5,1 dBr AVE: 6,13 dBr % above 9,0 dBr: 0,0 Last value: 5,6 dBr (2023/06/11 23:50:59) Station: 96.60 MHz, signal: 5/5 (81 dBuV) 23:38 23:40 23:42 23:44 23:46 23:48 23:50 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality